A friend of mine called me and told me that I needed to go out to a house of some folks who had no water pressure.  When we arrived we found that their pump was running but had not pressure and would build no pressure, very little water was coming out.  The first thing we did was to lower the pump to see if it was in enough water but there was no change so that told me that they must have either a hole in one of their couplings or the pump was worn out.  We knew that it was not the pump since it was replaced only 11/2 years prior so we pulled the pump and found that sure enough there was a small hole in the coupling that kept the pressure tank from filling up and providing enough pressure in the house.  If you think this could be a problem then call your water well service company or call us at (940) 389-6850 so we can help.